PVC Power Cables
Business Type Manufacturer, Exporter, Supplier, Retailer, Wholesaler

Preferred Buyer From

Location India, South Africa, Bangladesh, Nepal, Sri Lanka

The assistance of our sophisticated packaging system and skilled personnel, we are able to meet the standard as well as customized packaging requirements of the clients with ease. Our quality auditors conduct regular examinations of the product to keep the quality standards high and as per the international norms.

 

Features :

  • High conductivity
  • Easy to install
  • Dimensional accuracy
Read More...


Technical Specification

Constructional and other details 1100 Volts Single Core Unarmoured / Armoured Cable type :
Nominal Conductor Area mm2 25 35 50 70 95 120 150 185 240 300
Unarmoured
Nom. Insulation thickness mm 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2 2.2 2.4
Nom. Overall Cable dia mm 12 13 15 16 18 20 22 24 27 30
Aprox. Weight kg/km 180 220 280 370 470 580 700 840 1070 1290
Armoured
Nom. Insulation thickness mm 1.5 1.5 1.7 1.7 1.9 1.9 2.1 2.3 2.5 2.7
Nom. Overall Cable dia mm 15 16 17 20 22 23 25 27 31 32
Aprox. Weight kg/km 300 340 430 540 690 800 940 1100 1380 1650
Current Carrying Capacity  
     - In ground amps. 86 100 120 140 175 195 220 240 270 295
     - In air amps. 84 105 130 155 190 220 250 290 335 380

Technical Specification

1100 Volts Two Core Unarmoured / Armoured Cable type :AYY/AYFY to IS : 1554(Pt.1)/88
Nominal Conductor Area mm2 16 25 35 50 70 95 120 150 185 240 300
Unarmoured AYY
Nom. Insulation thickness mm 1 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2 2.2 2.4
Nom. Overall Cable dia mm 19 20 21 24 27 31 33 36 40 44 49
Aprox. Weight kg/km 410 410 490 640 800 1080 1240 1510 1840 2340 2890
Armoured AYFY
Nom. Overall Cable dia mm 21 22 23 26 29 33 34 38 41 46 51
Aprox. Weight kg/km 820 700 810 990 1230 1560 1750 2060 2480 3040 3720
Current Carrying Capacity  
     - In ground amps. 70 90 110 135 160 190 210 240 275 320 355
     - In air amps. 59 78 99 125 150 185 210 240 275 325 365

Technical Specification

1100 Volts Three Core Unarmoured / Armoured Cable type :AYY/AYFY to IS : 1554(Pt.1)/88
Nominal Conductor Area mm2 16 25 35 50 70 95 120 150 185 240 300
Unarmoured AYY
Nom. Insulation thickness mm 1 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2 2.2 2.4
Nom. Overall Cable dia mm 20 21 23 26 29 33 35 40 43 49 53
Aprox. Weight kg/km 370 540 650 830 1100 1410 1680 2080 2490 3260 3990
Armoured AYFY
Nom. Overall Cable dia mm 23 24 25 27 30 34 36 41 44 50 54
Aprox. Weight kg/km 660 850 990 1260 1540 1910 2250 2730 3150 4030 4800
Current Carrying Capacity
     - In ground amps. 60 76 92 110 135 165 185 210 235 275 305
     - In air amps. 51 70 86 105 130 155 180 205 240 280 315

 


Technical Specification

1100 Volts 31/2 Core Unarmoured / Armoured Cable type :AYY/AYFY to IS : 1554
Nominal Conductor Area mm2 25/16 35/16 50/25 70/35 95/50 120/70 50/70 185/95 240/120 300/150 400/185
Unarmoured AYY
Nom. Insulation thickness mm 1.2/1.0 1.2/1.0 1.4/1.2 1.4/1.2 1.6/1.4 1.6/1.4 1.8/1.4 2.0/1.6 2.2/1.6 2.4/1.8 2.6/2.0
Nom. Overall Cable dia mm 23 24 28 31 35 38 42 46 52 59 66
Aprox. Weight kg/km 630 730 980 1240 1620 2020 2340 2930 3750 4720 5900
Armoured AYFY
Nom. Overall Cable dia mm 24 25 29 32 36 39 44 48 53 60 67
Aprox. Weight kg/km 980 1140 1440 1720 2180 2600 3080 3680 4540 5600 6900
Current Carrying Capacity
     - In ground amps. 76 92 110 135 165 185 210 235 275 305 335
     - In air amps. 70 86 105 130 155 180 205 240 280 315 375

 


Technical Specification

1100 Volts Four Core Unarmoured / Armoured Cable type :AYY/AYFY to IS : 1554(Pt.1)/88
Nominal Conductor Area mm2 16 25 35 50 70 95 120 150 185 240 300 400
Unarmoured AYY
Nom. Insulation thickness mm 1 1.2 1.2 1.4 1.4 1.6 1.6 1.8 2 2.2 2.4 2.6
Nom. Overall Cable dia mm 20 24 26 30 32 38 39 43 49 55 62 71
Aprox. Weight kg/km 480 680 830 1120 1400 1870 2190 2660 3290 4200 5320 6780
Armoured AYFY
Nom. Overall Cable dia mm 21 25 27 31 33 39 41 44 50 56 63 72
Aprox. Weight kg/km 780 1049 1240 1590 1880 2460 2830 3310 4030 5050 6220 7860
Current Carrying Capacity
     - In ground amps. 60 76 92 110 135 165 185 210 235 275 305 335
     - In air amps. 51 70 86 105 130 155 180 205 240 280 315 375

 